One report gap for riding and another for parking
The 311B can use two report gaps, one for when the bike moves and one for when it stands still. Out of the box it reports every 10 seconds on the move and once an hour when parked. The fix command changes this. For example, fix020s002h***n with your password on the end means every 20 seconds while riding and every 2 hours while parked, with no limit on the count. Fleet Scanner saves each point, so you can play back any ride.